MIL-STD-810G Finally Recognizes
Multiaxis Shaking
by Wayne Tustin, Equipment Reliability Institute
Three tests—shaking a product first in the X axis, then in
the Y axis, and finally in the Z axis—are not realistic. But MIL-STD-810,
published in 1962, revised six times since 2000, and currently in its F
revision, has only offered the single-axis-at-a-time method. However, the G
revision, scheduled
for release in May 2008, will include the new Multiexciter Test Method 527.
Testing Automobiles
We all know that real-world
vibrations exist simultaneously in multiple axes. For instance, our automobiles
receive six inputs from the road: vertical, fore-and-aft, and left-and-right
linear in addition to pitch, roll, and yaw angular.
Automotive testing long ago evolved from vertical-only
mechanical shaking to multiple exciter single-axis (MESA) to the current
multiple exciter multiaxis (MEMA). Today, many automobile manufacturers
worldwide use multiple long-stroke electrohydraulic (EH), sometimes called
servohydraulic, shakers to accomplish such tests.
Multiple EH shakers drive each of the four wheels of complete
vehicles. Major automotive assemblies needing vibration tests are mounted on a
MEMA vibrating platform.
Multiple Electrodynamic Shakers
That is well and good for automotive shaking to
200 Hz, perhaps to 500 Hz. But for airborne applications, you need to shake to
2,000 Hz. For that reason, electrodynamic (ED) shakers are used.
For example, the U.S. Army Research Lab at Adelphi, MD,
pioneered the use of three mutually perpendicular ED shakers in response to a
land-vehicle assembly that frequently failed in the field.
Single-exciter-single-axis (SESA) shaking could not replicate the failure.
Army researchers hoped that MEMA shaking would replicate the
failure. The hope bore fruit, and several similar instances have occurred over
the years. This system can shake vertical only, north-south only, east-west
only, or any combination of axes including all three simultaneously.
A second system was installed at White Sands Proving Ground
in New Mexico. However, to my knowledge, that MEMA system has had little use
partly because 810F is SESA oriented.
The U.S. Navy recently acquired a MEMA system at Keyport, WA.
The U.S. Air Force owns and Boeing operates an eight-shaker MEMA system that
goes a step or two further. It also vibrates roll-only, pitch only, yaw-only, or
all six axes (6DoF) simultaneously.
The three or six ED shakers are connected to a common fixture
to which the test article is attached. Isn’t the north-south shaker, for
example, damaged by the east-west shaker and the up-down shaker and vice versa?
The answer is no. Between each shaker and the common fixture
is a zero-backlash mechanical connection that transmits axial vibration but
accommodates needed misalignment. When
the controls for a triaxial shaker array are set for pure up-down motion,
unwanted lateral motion of the up-down shaker is actively controlled by the
north-south and the east-west shaker systems.
Commercial Multiaxis ED Shaking
Perhaps the military with their relatively vast
budgets can make such investments. But many commercial enterprises may think
they can’t afford three ED shakers, each with its own power amplifier and
control channel.
Many years ago, I sold ED shakers. Some potential customers
balked at buying even one, citing the considerable expense. Within a year or
two, many of those same customers owned several shakers because the first was in
such heavy demand.
Three-axis shaker systems similar to the
one shown in Figure 1
are said to be quite common among Japanese automobile manufacturers. On a
related note, Spectrum Technologies claims to be the only U.S. commercial
environmental test lab having three-axis ED shaking capabilities.
|

Figure 1. Three-Axis ED Shaking
Courtesy of IMV, Visteon, and Spectrum Technologies
|
Economical Solutions
Status Quo
Although not recommended, continue to use your
existing ED shaker. It, like all ED shakers, has some lateral
motion—uncontrolled. Perhaps you’ve discovered this for yourself by attaching
lateral accelerometers in addition to your axial accelerometer. Does this
provide sufficient lateral vibration for Method 527? No.
Tilt Fixture
Figure 2
illustrates a tilt fixture that skews the test article relative to shaker
vibratory motion. In my opinion, this is not multiaxis vibration. True, there is
a component of motion in the X, Y, and Z axes, but the correlation is 100%. You
are not simulating the real world where a specimen’s X, Y, and Z inputs often
are much different.

Figure 2. Tilt Fixture
|
Variable Repetition Rate Hammering
Another approach is variable repetition rate hammering. It
could be described as several nonsynchronized pneumatic hammers on different but
adjustable compass headings tilting upward into the bottom of a softly sprung
6DoF horizontal multiaxis platform. The nonsynchronized programmed repetition
rate hammering results in translational and rotational motion.
The platform serves as the bottom of a varying-temperature
chamber. Test articles atop the platform receive thermal cycling plus multiaxis
vibration. Several manufacturers offer these highly accelerated life testing
(HALT) and highly accelerated stress screening (HASS) chambers. They effectively
stimulate failures; there is no attempt to simulate the real world.
Without question, variable repetition rate hammering induces
failures by simultaneously exciting all test article resonances. Such units are
being used widely to find design and production weaknesses in electronic
assemblies. But many reliability engineers question the use of a tool whose
vibration is poorly controlled in both the time and frequency domains.
Repeatability is questionable.